Amylase, Urine 
Alternate Test Names
Urine Amylase; Amylase/Creatinine Clearance Ratio; ACCR 
PLS Test Code
UAMY 
Laboratory
Biochemistry 
Specimen
Urine 
Analysis Performed On
Urine 
Container
Urine container Plain 24 hour 
Container Colour
 
Multiple Specimens
Urine container Plain 24 hour Or Random urine collection PLUS serum tube for ACCR 
Required Volume Adult (mL)
10 
Req Vol Paediatric (mL)
Reference Ranges
Male: =490 U/L, =32 U/mmol Creatinine, Female: =450 U/L, =43 U/mmol Creatinine, ACCR: 2-5% 
Turnaround Time Routine
24 Hours 
Turnaround Time Urgent
 
Turnaround Other
 
Days test is performed
Daily 
Transport
Keep at room temperature 
Special Requirements
For Amylase/Creatinine Clearance Ratio (ACCR) calculation a Plain tube for Serum Amylase is also required. 
Patient Preparation
None 
Collection Instructions
Timed Collection: Label 24 hour urine bottle with patient's full name and date and time of commencement. Collect the 24 hour urine specimen in the following manner: a) Determine a time to start the test (eg. 0800 hours) b) Empty the bladder at this time and discard this urine. c) From now on all urine passed in the next 24 hours may be collected in a container, but must be transferred to the 24 hour acid urine bottle. d) At 24 hours from commencment time (eg. 0800 hours the next morning) the bladder is emptied and this urine is also transferred to the 24 hour urine bottle. Deliver the specimen to the collection centre on the day the test is completed. Store specimen in a cool dark place during collection. 
Clinical Information
 
Sent to Reference Laboratory
No 
Ref Laboratory Name
 
Estimated Patient Fee
N/A 
Last Updated
02-Oct-2016  (Version:1.01 )

copyright © 2017 St Vincent's Pathology

developed by Alex McCullie, AMC Developers